Arabic
HomeAbout UsProductsWater ProblemsTestimonialsContact Us
 
 
• Hacked By Rishabh SaaB
------------------------------------------------- more »
 
 

 

 

 

Replacement Membranes

FILMTEC MEMBRANE ELEMENTS

FILMTEC BW30-4040 Membrane Element

FILMTECTM brackish water reverse osmosis membrane elements provide consistent, outstanding system performance in light industrial applications.

  • FILMTEC BW30-4040 is the industry standard for reliable operation and production of the highest quality water.

Elements with a hard shell exterior are recommended for systems with multiple-element housings containing three or more membranes, as they are designed to withstand higher pressure drops.


Product Name Nominal Active
Surface Area ft2 (m2)
Permeate Flow Rate
gpd (m3/d)
Stabilized Salt Rejection (%)
FILMTEC
BW30-4040
82 (7.6) 2400 (9.1) 99.5
  1. Permeate flow rate and salt rejection based on the following test conditions: 2000 ppm NaCl, 225 psig (15.5 bar), 77°F (25°C), and 15% recovery.
  2. Permeate flow rates for individual elements may vary +/-20%.
  3. For the purpose of improvement, specifications may be updated periodically.


FILMTEC TW30-4040 Membrane Elements

A complete range of FILMTEC™ 4040-size elements is available to meet a wide variety of customer needs for commercial applications, from the highest purity water to the lowest total system costs..

  • FILMTEC TW30-4040 is the industry standard for reliable operation and production of the highest quality water.

Tape-wrapped elements are built with the same high quality membranes and materials of construction as industrial elements, except for the hard outershell, and are more economical for commercial systems with one or two elements per housing.


Product Name Nominal Active
Surface Area ft2 (m2)
Permeate Flow Rate
gpd (m3/d)
Stabilized Salt Rejection (%)
FILMTEC
TW30-4040
82 (7.6) 2400 (9.1) 99.5
  1. Permeate flow and salt rejection based on the following test conditions: 2000 ppm NaCl, 225 psi (15.5 bar), 77°F (25°C), 15% recovery.
  2. Permeate flows for individual elements may vary +/-20%
  3. For the purpose of improvement, specifications may be updated periodically.

Element
Type
Min Salt Rejection, % Nominal Salt Rejection, % Permeate Flow, GPD (m3/d)
ESPA1 99.0 99.3 12,000 (45.4)
ESPA1-4040 99.0 99.3 2,600 (9.8)
ESPA2 99.5 99.6 9,000 (34.1)
ESPA2+ 99.5 99.6 12,000 (45.4)
ESPA2-4040 99.4 99.6 1,900 (7.2)
ESPA3 98.0 98.5 14,000 (53.0)
ESPA3-4040 98.0 98.5 3,000 (11.4)
ESPA4* 99.0 99.2 12,000 (45.4)
ESPA4-4040* 99.0 99.2 2,500 (9.4)

TEST CONDITIONS
The stated performance is initial (data taken after 30 minutes of operation), based on the following conditions:

NaCl Solution, PPM* 1500
Applied Pressure**, psig (MPa) 150 psi (1.05)
Operating Temperature, °F (°C) 77° (25°)
Permeate Recovery 15%
pH Range 6.5-7.0
*ESPA4 NaCl Solution tested at 500 PPM
**ESPA4 tested at 100 psig

APPLICATION DATA

Maximum Applied Pressure, psig (MPa) 600 (4.14)
Maximum Feed Flow, GPM (m3/h) 4040-16(3.6), 8-inch-75(17.0)
Maximum Operating Temperature, °F (°C) 113° (45°)
Feedwater pH Range* 3.0-10.0
Maximum Feedwater Turbidity, NTU 1.0
Maximum Feedwater SDI (15 mins) 5.0
Maximum Chlorine Concentration, PPM <0.1
Maximum Ratio of Concentrate to Permeate Flow for Any Element 5:1
Maximum Pressure Drop for Each Element, psig 10



 

  HOME | ABOUT US | PRODUCTS | WATER PROBLEMS